ORTRUN.HLP --- 10/22/93 --- Version 2.00 ISR TESTING To test the overhead resulting from the ADC ISR, when the first display window appears, press a key twice, very quickly. When the main window appears, it will say "TESTING ISR - PLEASE WAIT". This may take anywhere from a few seconds to several minutes. When it has completed this test, the display will read "ARMED -- BEGIN TEST". If there is excessive overhead, an error message will appear, and the program will terminate. This test is performed whether or not the specific test is selected as described above. CALIBRATION To access, press -C When password is requested, enter it, and press Calibration factors and other variables are accessed by entering the corresponding number and pressing A "hidden" selection is 99, which gives the number of bytes of memory remaining, and the approximate A/D ISR overhead. DROPOFF The amount of dropoff in the test waveform is determined by reading the RMS value of the first and last full cycles of the waveform, and storing this value as a ratio. A value of 1.00 indicates no dropoff; 0.5 means that the last cycle is 1/2 the RMS value of the first cycle. DATA FILE The format of the data file is as follows: 200.00 SHOT 1 Amperes 0.100 SHOT 1 ON Time 0.500 SHOT 1 OFF Time 190.00 SHOT 2 Amperes 0.120 SHOT 2 ON Time 0.550 SHOT 2 OFF Time 210.00 SHOT 3 Amperes 1.000 SHOT 3 ON Time 0.450 SHOT 3 OFF Time 200.00 SHOT 4 Amperes 1.000 SHOT 4 ON Time 0.550 SHOT 4 OFF Time 190.00 SHOT 5 Amperes 0.100 SHOT 5 ON Time 3.000 SHOT 5 OFF Time 0.750 SHOT 1 Dropoff 0.800 SHOT 2 Dropoff 0.500 SHOT 3 Dropoff 0.550 SHOT 4 Dropoff 0.600 SHOT 5 Dropoff